FloodShield Aluminium Barrier
Removable aluminium panels for suitable homes, driveways, doors and business openings. Fit them before floodwater arrives, then remove and store them when it is safe.
FloodShield starts at NZ$736 incl. GST for a suitable single doorway setup. Delivery, installation and any extra hardware are separate. We’re a local New Zealand supplier and deliver nationwide. We confirm fit and the final price before you order.
DOMESTIC FLOOD PROTECTION
Homes, driveways, doorways and garages
FloodShield uses removable aluminium panels to protect suitable doorways, garage openings and residential driveways. We check the opening, supporting structure and expected water conditions before specifying a barrier.






How a home installation works
Prepared side posts or channels retain the removable panels. Fit and secure the supplied panels before floodwater arrives, following the instructions for that configuration. Remove, clean and store them when it is safe to restore access. The side fixings stay in place.
Initial installation and surface preparation are separate from putting the panels in place before an event. Plan storage, handling, access and a safe exit route.
What to send Allan
- Photos of both sides of the opening and surrounding walls.
- Clear width at the base and proposed barrier height.
- Threshold, floor and wall materials; steps, slopes, drains or cracks.
- Known flood levels and space for posts, panels and storage.
Final measurements, panel profile, seals, fixings and suitability are confirmed for your opening.
Keep the configurations separate: the 200 × 100 mm reference profile in the larger-project section is not a domestic specification. A home barrier is not a guarantee of a dry building; water can enter through other openings, walls, drains or services.
COMMERCIAL & LARGER PROJECTS
Commercial and larger engineered projects
For shopfronts, warehouses and longer barrier runs, we start with the openings, ground conditions and expected water levels. Panels, posts and foundations must be designed for the site.
A small business doorway may use a similar setup to a home entrance. The details below describe larger panel-and-post systems. Each opening needs its own specification.
Removable panels, planned around your site. Aluminium panels stack between sealed posts to close the opening. The panels and removable middle posts are stored away afterwards; permanent end fixings and anchors remain.

The panel-and-post system
Panels stack within gasketed post channels.
Middle posts divide wider openings into bays.
End connections and anchors transfer loads into the supporting structure.
Top pressing tools bear down on the panel stack and work with the seals.
Component sizes, post spacing, foundations and sealing details are selected for the site. Do not use a reference profile as a complete installation specification.
Overview
FloodShield is a demountable aluminium panel-and-post barrier for openings that need temporary flood closure. Stacked panels fit into gasketed post channels. Removable middle posts divide wider openings into bays, with permanent interfaces connecting the barrier to the supporting structure.
Panel profiles, post sections and bay spacing depend on the required water level and site conditions. Initial installation of end connections, foundations and anchors is separate from deploying the removable components before an event.
Materials & Finishes
The reference panel family uses 6063-T6 aluminium, with a 200 mm-high × 100 mm-deep profile. Final profile, gauge and panel lengths require confirmation for the selected configuration. Photographs of other variants do not establish those dimensions.
EPDM seals are used at the panels and posts, with a PE/PU-type ground seal. Final seal selection, finish and base preparation are confirmed for the site.
Panel Heights & Sizing
Panel stacks, post sections and bay spacing are selected for the proposed water level and design loads. The 200 × 100 mm reference profile is not a universal specification for every FloodShield installation.
A 3 m solution requires site-specific engineering. Appropriate components, adequate foundations, end tie-ins and engineer verification are needed. It is not a standard protection rating for every system.
Agree the operating water limits, final assembled dimensions and acceptance criteria before manufacture. Do not increase the stack above the approved design height.
Mounting, Posts & Supports
Gasketed end and middle posts retain the panels. Removable middle posts divide wider openings into bays. Post sections and bay spacing must suit the design loads and supporting structure.
Embedded anchors and end tie-ins transfer loads into engineer-designed supporting structures. Fixings, reinforcement and foundation geometry require engineering for the site. An illustrative anchor assembly is not a construction detail.
Allow for access, door movement, services and any specified supports. Heavy posts may need mechanical lifting.
Measuring Your Opening
Start with your location, photographs and approximate dimensions. Before the system is specified:
- Survey the opening, base and any crossing services.
- Record clear widths, changes in level and the proposed barrier height.
- Identify the supporting wall and ground materials, drains, joints and water-entry routes.
- Resolve sealing details before fabrication.
- Confirm water loads, foundations, end tie-ins and the selected components with the appropriate engineer.
Agree operating limits, acceptance criteria, storage and maintenance. Final manufacturing dimensions and fixing positions need verification.
Installation & Deployment
Prepare: confirm the approved site procedure, access, component set and the condition of fixtures and seals.
Deploy: position posts and insert panels using the approved method. Fit the specified top clamps and complete the required checks. Pressing tools bear down on the panel stack as part of the selected sealing assembly.
Recover: after safe clearance to remove the barrier, clean, inspect and store panels, posts, seals and tools ready for reuse.
Heavy posts may require mechanical lifting. Upper-panel access, staffing and handling equipment need a project-specific assessment. Practise in advance and deploy before floodwater arrives; do not enter moving floodwater to fit or adjust a barrier.
Site Suitability & Limitations
Sound foundations, end tie-ins and a suitable sealing surface are essential. Uneven, damaged or porous areas may need preparation. Water may also enter through walls, vents, drains, services or other openings.
A barrier does not guarantee a completely dry building. Plan for residual water and a safe exit route. Water depth, flow, waves and debris require site-specific assessment. Product photographs do not establish a certified leakage rate, protection depth or suitability for a particular site.
Cleaning, Storage & Seal Care
Follow the supplied model instructions and approved site procedure. After use, clean away silt and debris, rinse as appropriate and allow the components to dry. Inspect seals for cuts, flattening or displacement and check posts, fixings and clamps for damage or loosening.
Store panels where they will not be bent or have their sealing edges damaged. Keep each opening’s parts labelled together and accessible. Repeat inspection and a practice fitting before the wet season and after changes to paving, doors or walls.
Ask us about suitable replacement seals and hardware for your system. Use cleaning and maintenance products compatible with the supplied finish and seals.
Supply, Pricing & Local Installation
Ask us for a product price or help comparing suitable options—whichever you need. Quotes depend on opening size, mounting, posts, supports, finish and delivery, with installation or surface preparation identified separately where applicable.
We supply throughout New Zealand. Local installation and site visits are available by arrangement in the wider Manawatū–Whanganui region. For other locations, we can work through the requirements with you and your installer.
Lead times, included components and warranty terms will be confirmed with your quotation.
Technical Information & Demonstrations
Download the SSFP FloodShield brochure (PDF)
Download the current SSFP FloodShield brochure above, and ask Allan for technical information relevant to your proposed configuration. Project planning should cover the selected components, panel and post dimensions, foundations, end connections, sealing details, handling and deployment procedure.
Generic family illustrations and demonstrations of other profiles must not be treated as evidence for a selected 100 mm-deep system.
FloodShield components and installations
Real product and installation photographs from the SSFP brochure. These show different configurations; a photograph does not confirm the 200 × 100 mm reference profile or a protection rating.




Earlier SSFP supply and preparation examples
These existing photographs show Allan preparing aluminium barrier components for an earlier private residential supply project. They illustrate preparation and handling, not the confirmed profile, height or engineering of the reference family described above.
Configurations vary. Specify the panel profile, post arrangement, foundations, seals and handling method for each new opening.



Talk through your site