FloodBloc Wall F50 and F80
A temporary barrier line made from connected sections. FloodBloc Wall uses modular boards, corners and end pieces to suit the planned layout. Compare F50 and F80 below, then check the surface, available space and water conditions with Allan.

Choose the series
F50
50 cm nominal protection height
52 cm physical board height
F80
80 cm nominal protection height
82 cm physical board height
Confirm ground conditions, operating water limits and the final configuration before use.
Matching components support straight runs, corners and end connections. Nominal series heights do not establish safe operating limits for every site.
Overview
FloodBloc Wall combines modular L-shaped boards, corners and end pieces for temporary flood protection. The F50 and F80 series use interlocking boards with stainless steel locking clamps and a dual sealing arrangement.
Choose the series to suit the site, then confirm ground conditions, operating water limits and the complete layout. Water over the horizontal base adds downward load; surface condition, water depth, flow and correct assembly affect performance.
Connections, seals and storage
A compressible sponge seal and P-shaped EPDM gasket work together to limit leakage. Stainless steel locking clamps secure adjacent boards. Reinforced contact points and folded-angle joint faces form part of the connection design.
- Matching straight boards, corners, end pieces and transition components.
- Anti-slip base seal and ground/joint seals.
- Connected groups of two or three boards can be stored on their sides.
The base load and seals do not guarantee stability or watertightness. Confirm the complete configuration and allow for seepage.
F50 and F80 dimensions
| Series | Nominal protection height | Straight board | Board height | Base depth | Board width |
|---|---|---|---|---|---|
| F50 | 50 cm | FZ50 | 52 cm | 68 cm | 70.5 cm |
| F80 | 80 cm | FZ80 | 82 cm | 98 cm | 70.5 cm |
Dimensions above apply to the named straight boards. Corners and end/transition pieces have their own dimensions. Board width is not automatically the installed coverage of a connected run.
Confirm current component dimensions, operating water limits and site suitability before ordering. F100 availability is by enquiry.
Corners, ends and changes in level
Matching corners, right- and left-hand end pieces, wall connections and adjustable transition components allow the barrier line to be planned around the site. Each component must match the selected series and layout.
The stepped-height example in the current brochure uses two braced end pieces. It does not establish a continuous-slope capability or make every change in ground level suitable.
Ask about optional FS boards and confirm compatibility and availability for your layout. Do not substitute another range’s fin, skirt or size specifications.
Ground & Site Suitability
Check the proposed ground surface, changes in level, expected water depth and flow, barrier length, base footprint and end connections. Ground condition and the sealing contact affect performance.
Identify paving joints, drains, steps, loose or soft ground and slopes before selecting the layout. Water may pass beneath, around the ends or through other routes. Allow for seepage and keep a safe flood-response plan.
Planning & Deployment
- Confirm the deployment location and complete layout.
- Clear debris and clean the ground.
- Stand on the dry side, with the horizontal board base facing the water.
- Start with the appropriate left end piece.
- Connect successive boards to the right: align the plug and socket, join the boards and secure the locking clamp.
- Finish with the appropriate right end piece against the wall.
Follow the instructions for the selected system and end arrangement. Practise assembly in advance, inspect seals and fittings, and keep access and evacuation routes clear. Deploy before water arrives; do not enter moving floodwater to install or adjust a barrier.
Choosing the Right Configuration
Send Allan your location, the length to cover, preferred series, surface details, changes in level and photographs of proposed end connections. We can discuss the matching components and the layout to assess.
Keep the product series clear when comparing options. F50/F80 specifications on this page must not be mixed with dimensions or test results for other modular barrier ranges.
Technical Information
Download the SSFP FloodBloc Wall brochure (PDF)
Download the current SSFP FloodBloc Wall brochure above and confirm dimensions for the selected straight boards, corners, ends and transitions. Confirm operating water limits, handling, assembly and storage for the proposed layout.
Demonstrations show assembly, configurations and water behaviour. They are not independent certification or proof of a permitted water depth, flow rate or watertight installation.
Pricing, Availability & Support
Contact Allan for availability and a quotation for the selected series, quantities, matching components and delivery. Included parts, expected lead time and applicable warranty terms are confirmed before ordering.
Supply is available throughout New Zealand. Local installation and site support are available by arrangement in the wider Manawatū–Whanganui region.
Product Demonstrations
Watch the three demonstrations below: water agitation and enclosures, a curved ring configuration, and braced-end assembly. Original audio is retained, including Chinese speech.
Demonstrations do not replace the instructions for the model supplied or establish suitability for your property.
Allan’s local work: Mount Albert New World
SSFP supplied aluminium barriers and a modular FloodBloc wall for different parts of this Auckland supermarket. Allan visited the site to work through the frontage, corners and tighter spaces with the team.


These local photographs show an earlier supplied configuration. The current F50/F80 range is specified separately for each new site.
Connections and configurations
Examples from the SSFP FloodBloc Wall brochure. Component compatibility and the complete layout need confirmation for your site.




Stacked for storage

Watch the demonstrations
Original audio is retained, including Chinese speech. These clips illustrate assembly and water behaviour; they are not independent certification or proof of a safe water depth, flow rate or watertight installation.
Building-side deployment and vehicle enclosure
Alongside a building

Building protection depends on the complete layout: surface conditions, changes in level, ends, openings, drainage and the expected water conditions. This example is not evidence of a rated depth or suitability for a particular building.
Vehicle enclosure — specialist assessment

Connected straight boards and corners form a temporary water enclosure around the vehicle shown. This illustrates a specialist containment configuration, not a standard home flood-protection installation.
For EV-related enquiries: fire-extinguishing performance has not been established. This image is not an approved firefighting procedure or instructions for an electric-vehicle fire. Fire response must be directed by qualified emergency services.
Talk through your site
Send us your location, required barrier length, preferred height, surface details and photographs. We can discuss the F50/F80 series, matching components and a layout to assess for your site.